Solution by Product · Security Power Backup & Load-Shedding Protection

Keep your security running through load-shedding

In 2026 rural areas are losing power 7–10 hours a day and Chattogram 6–8. A security system without backup goes dark every day — and so does the evidence.

Step 1 · Sizing

Load-shedding backup calculator

Enter your numbers. Results update as you type.

Load-shedding backup calculatorIndicative sizing — our engineers confirm on site survey
Reader + EM lock ≈ 12 W each
Rural cuts run 7–10 h in 2026
Load to protect—
UPS / inverter—
Battery bank—
Solar to recharge—

Cameras at 6 W each. Inverter efficiency 85%. Solar assumes about 4 peak sun hours a day — conservative for Bangladesh.

Step 2 · Scope

What a complete system includes

RequiredUPS or inverter

Sized on the running watts with headroom. An online UPS gives a clean switch-over; a line-interactive unit is cheaper and fine for most CCTV loads.

RequiredBattery bank

Sized on the hours you actually lose power, not a round number. The calculator converts load and hours into 12 V 100 Ah batteries.

RequiredSurge protection

The spike when grid power returns after load-shedding damages NVR and switch power supplies. Protect the UPS input.

OptionalSolar panels

Where outages run most of the day, mains never fully recharges the bank. Panels refill it in daylight.

OptionalBattery monitoring

Shows state of charge and warns before a battery fails, rather than on the night it is needed.

OptionalDedicated circuit

Security loads on their own circuit, so an air conditioner or pump cannot drain the backup.

Step 3 · Selection

Which option is right for you

The honest trade-offs.

ConsiderationLead-acidLiFePO4 lithium
Usable capacity~50% for long life~90%
WeightHeavyLight
Upfront costLowerHigher
Heat toleranceLife shortens in heatBetter
Step 4 · Avoid these

6 mistakes we see repeatedly

Every one has cost a real project real money.

Sizing the UPS by guesswork

A UPS picked as "1 kVA should do" either trips under load or costs twice what was needed.

Do this: Add up the running watts of every device and size from the total — the calculator does it.

Running lead-acid batteries flat every day

Deep daily discharge is the most common reason lead-acid batteries fail inside a year.

Do this: Size the bank so each outage uses about half its capacity, or choose lithium.

Batteries in a hot, closed room

Battery makers publish that lead-acid life roughly halves for every 8–10°C above 25°C.

Do this: A ventilated, shaded position — never beside the generator or inside a sealed cabinet.

Backing up cameras but not the network

Cameras keep running but record nothing because the NVR, PoE switch or router went down.

Do this: Protect every device between the camera and the recorded footage.

No surge protection

Power returning after load-shedding arrives with spikes that damage power supplies.

Do this: Surge protection on the UPS input, and earthing checked.

Never testing the backup

A backup is only discovered to be flat on the night of an incident.

Do this: Pull the mains once a month and time how long the system runs.

Products

Hardware we supply

Guide

Buyer & installer guide

Rules we apply on every installation. Share this with your installer.

01
Protect the whole recording path

Cameras record nothing if the NVR, PoE switch or router goes down. List every device between the camera and the recorded footage, and back up all of them.

02
Size for your area, not a round number

In 2026, Dhaka sees one to two hours of cuts, Chattogram six to eight and rural areas seven to ten. Enter your real outage length in the calculator.

03
Use only half of a lead-acid battery

Lead-acid batteries last far longer when discharged to about 50%. Running them flat every day is the most common reason they fail within a year.

04
Keep batteries cool

Battery makers publish that lead-acid life roughly halves for every 8–10°C above 25°C. A battery rack in a hot, unventilated room is replacing itself early.

05
Add solar where outages are long

When the grid is off for most of the day, the battery never fully recharges from mains. Solar panels refill it during daylight; the calculator sizes the array.

06
Test every month

Switch off the mains and time how long the system runs. A backup that has never been tested is an assumption, not a backup.

FAQ

Questions buyers ask before specifying

Depends on the load and battery. Enter your devices and required hours above.

Total running watts divided by about 0.6 for the VA rating. The calculator selects the next standard size.

Lithium costs more upfront but gives more usable capacity and handles heat better.

Yes, with enough panels and battery for your outage pattern.

ZKTeco TS1000 Pro draws 15 W on standby. Without backup the arm drops and the lane opens.

They open. Backup keeps doors secured.

Prices and figures as of September 2026. Confirm with a quotation.

Send us your device list

We will size the UPS, batteries and solar.